Smart Decorative Smoke Detector Case with Relay Output SD119

Product Details
Customization: Available
Type: Home Alarm
Anti-theft Alarm System Approach: Active
Still deciding? Get samples of US$ 8/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
121
Year of Establishment
2005-11-14
  • Smart Decorative Smoke Detector Case with Relay Output SD119
  • Smart Decorative Smoke Detector Case with Relay Output SD119
  • Smart Decorative Smoke Detector Case with Relay Output SD119
  • Smart Decorative Smoke Detector Case with Relay Output SD119
  • Smart Decorative Smoke Detector Case with Relay Output SD119
  • Smart Decorative Smoke Detector Case with Relay Output SD119
Find Similar Products

Basic Info.

Model NO.
SD119-4AR-12/24
Anti-Theft Alarm System Type
Smoke Alarms
Anti-Theft Alarm System-Wide
Wire Alarm Detectors
Types of Smoke Detectors
Photoelectric Smoke Style
Color
White
Weight
120g/Set with Base
Dimensions
100mm(Dia.)*46mm(Ht) with Base
Alarm Indicator
LED Continuously Emitting Red Light
Ceiling Spacing
40-50 Foot Rating for Heat Sensor
Temperature Range
-10°c to 50°c
Name
Conventional Smoke Detector
Humidity
0 to 95% Rh, No Condensation or Icing
Smoke Sensitivity
0.98--2.40%/FT Obscuration (UL) ; 0.08--0.14 dB/M
Signal Transmission
Wired Alarm
Transport Package
100PCS/Carton
Specification
UL/EN
Trademark
Sentek
Origin
Ningbo China
HS Code
8531901000
Production Capacity
100000/Month

Product Description

Smart Decorative Smoke Detector Case with Relay Output SD119
Specification:
 

Smoke Sensitivity: 0.98~4%/FT Obsuration(UL standard)
Ceiling Spacing: 50 foot rating for heat sensor (55 degree)
Reset Voltage: less than 1 volt
Reset Time: less than 1 second
Alarm Indicator: LED continuously emitting red light
Remote Output: 25 mA max., diode gate
Temperature Range: -10°C to 55°C,UL268 temperature 0~37.8 °C
Permissible Current: 80mA maximum
Humidity: 0 to 95% RH, no condensation or icing
Alarm Contact: (for 4-wire)NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC
Dimensions: 100mm (dia) x 46mm (ht) with base
Weight: 130g/set with base

Smart Decorative Smoke Detector Case with Relay Output SD119

Smart Decorative Smoke Detector Case with Relay Output SD119
Smart Decorative Smoke Detector Case with Relay Output SD119
Product Features: 

*2 or 4 wire 
*Advanced detection and discrimination algorithms 
*Easy installation and maintenance
*Sleek low-profile housing design
*Durable sensor head, no need for replacement 
*SMD circuit board design: satisfactory quality and reliability guaranteed
*N/C and N/O relay output  
*Auto reset function for security systems (4 wire optional ) Sensor base option:standard and Schottky Diode
*Five-year warranty

Order Information:

The range includes:

SD119-2:                  2 wire photoelectric smoke alarm

SD119-2-LED:          2 wire photoelectric smoke alarm with remote LED output

SD119-2H:                2 wire photoelectric smoke and heat alarm

SD119-2H-LED:        2 wire photoelectric smoke and heat alarm with remote LED output

SD119-4:                  4 wire photoelectric smoke alarm(12/24/48VDC)

SD119-4B:                4 wire photoelectric smoke alarm with Buzzer(12/24/48VDC)

SD119-4AR:              4 wire photoelectric smoke alarm with auto-reset function(12/24/48VDC)

SD119-4ARB:           4 wire photoelectric smoke alarm with auto-reset function and Buzzer(12/24/48VDC)

SD119-4H:                4 wire photoelectric smoke and heat alarm (12/24/48VDC)

SD119-4HB:             4 wire photoelectric smoke and heat alarm with Buzzer(12/24/48VDC)

SD119-4HAR:           4 wire photoelectric smoke and heat alarm with auto-reset function(12/24/48VDC)

Model

2/4

Wire

Heat Sensor Setting

Voltage DC

(Min./MAX.)

Standby Current

(Max.)

Alarm Current

(12/24V)

Surge Current

(Max.)

Start-Up Time

(Max.)

Permissible Current

(Max.)

Cycle Time Alarm Contact Certified
SD119-2 2   10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. - UL/EN
SD119-2L 2   10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. Remote LED UL/EN
SD119-2H 2 135±5°F 10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. - UL/EN
SD119-2HL 2 135±5°F 10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. Remote LED UL/EN
SD119-4-12/24 4   12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A UL/EN
SD119-4H-12/24 4 135±5°F 12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A UL/EN
SD119-4AR-12/24 4   12/24V 100µA 30/45mA - 30Sec. - 1-3Sec.

Form A

Auto Reset

CE
SD119-4ARB-12/24 4   12/24V 100µA 30/45mA - 30Sec. - 1-3Sec.

Form A

Auto Reset

CE
SD119-4B-12/24 4   12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A CE
SD119-4HB-12/24 4 135±5°F 12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A CE
SD119-4HARB-12/24 4 135±5°F 12/24V 100µA 30/45mA - 30Sec. - 1-3Sec.

Form A

Auto Reset

CE

Related Products

Smart Decorative Smoke Detector Case with Relay Output SD119
Company Information
Smart Decorative Smoke Detector Case with Relay Output SD119

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier