Fire Alarm Control Panel, 2 Loops Fire Alarm Control Panel, Addressable Fire Alarm Control Panel manufacturer / supplier in China, offering Addressable Fire Detection and Alarm Control System, Honeywell, DSC, 2gig, Ge Control Panel Wireless Magnetic Sensor (WC10), 345MHz of 2gig, Control Panel Wireless Magnetic Sensor (WC10 -H) and so on.

Diamond Member Since 2010
Audited Supplier
Supplier Homepage Products Fire Alarm Control Panel Addressable Fire Detection and Alarm Control System

Addressable Fire Detection and Alarm Control System

Get Latest Price
Min. Order: 5 Pieces
Port: Ningbo, China
Payment Terms: L/C, T/T, Western Union, Paypal
Type: Fire Alarm Host
Function: Non-Networked
Usage: Fire
Product Name: Addressable Fire Detection and Alarm Control Syst
Main Power Supply: AC220V± 15%, 50Hz.
Dimensions: 450mmx370mmx120mm

You Might Also Like

Loading...

Basic Info

Model NO.
JB-TBL-8600
Capacity
1A/24V
Battery Power Output
1 Group 24V Power Output Output
Trademark
Sentek
Origin
Ningbo China

Specification: 

Product Name:Addressable Fire Detection and Alarm  Control SystemMain power supply:AC220V± 15%, 50HZ.
Battery power supply:DC 24V (2 sealed batteries: 2*12V*4Ah)Product capacity:2 loops*254 points = 508 points
Loop capacity:Up to 254 points in any combination of 2-wire
smart smoke detector, heat detector, call point, input module,output module and sounder.
Direct output:6 groups of wet contacts relay output.
Contacts capacity :1A/24VDC, output current 500mA. Battery power output: 1 group 24V power output Output
capacity:1A/24V. Operating Environment:Temperature -10°C~+50°C Humidity ≤95%.
 Dimensions: 450mm×370mm×120mm. Product standard: GB4717-2005, GB16806-200.

Addressable Fire Detection and Alarm  Control System

Addressable Fire Detection and Alarm Control System
Appearance and dimensions:

Addressable Fire Detection and Alarm Control System

System composition

Chassis
Function module8600.1 master board (with LCD)
8600.2 power board
8600.4 Master and Bus Control Keypads
8600.5 direct linkage control panel
8600.6 loop board
8600.7 linkage output board
Micro printer
Power supply:24V switching power supply 100W, Battery2*12V*4Ah

 Main functions:

1 System self-test

The system will test indicator light,LCD screen,sound and so on.

2 Inquiry function

You can see the device type, zone number, definition about whether there are devices, position information corresponding to each address in the loop.

3 Event record

Under this menu, you can see the fire alarm information and other operation record.

4 Data sampling

Data sampling can sample the products in the loop, and displayed as data. The data can be used to judge the status of the products.

5 Setting function

In this function, you can set the password, time and the printer.6 Installation and program functions

(1) Address coding: the control unit can read or write the product address.

(2)Login: Connecting the products to the control unit. Auto login can login the address and type of the products.

(3)Logic programming: Set the logical relationship between the product and the control unit. Including system linkage, bus linkage and direct linkage.

7 Feedback function

The control unit will display the feedback information after start the equipment manually or automatically and send the alarm sound, lights up the feedback light. Feedback is real information about the starting of fire-fighting equipment.

8 Faulty alarm function

The control unit can automatically check the working status of main power supply,battery power supply detectors and modules. If the control unit found any abnormal address during the inspection process, after many confirmations, it immediately reported the fault information of the control unit number, loop number, and address number. The "faulty" indicator light is on, and you can hear the faulty sound. Press the "mute" key to mute.

Related Product

Addressable Fire Detection and Alarm Control System

Company Information
Addressable Fire Detection and Alarm Control System

Send your message to this supplier

*From:
*To:
avatar Mr. Peilin Jiang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now