Addressable Fire Alarm System for Micro Output Module/ Loop Sounder

Type: Home Alarm
Signal Transmission: Addressed Module
Certification: CE
Supply Voltage: Loop Powered 17 – 30 V
Alarm Current: 13mA Am111-C Am111-D
Reset Time: 20 Seconds
Samples:
US$ 5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
AM113
Address Range
1-125
Temperature /Relative Humidity
10°c to 55°c / 0 to 95% Rh
Dimensions / Weight
49 (L) X 25 (W) X 13 (H) mm / 18g
Transport Package
Color Box
Specification
AM113
Trademark
Sentek
Origin
China
HS Code
8531100000
Production Capacity
100000/Year

Product Description

Description:
Addressable Module AM113 allows the connection and addressing of Conventional Detectors, Call Points, Input, Output and Conventional
Sounder/ Beacon
Specification:
 
Model DESCRIPTION
AM113-D Addressed Module for SMOKE or HEAT Detector (WHITE)
AM113-C Addressed Module for CALL POINT or INPUT (RED)
AM113-S Addressed Module for Micro Output Module/ Loop Sounder (YELLOW)
Supply Voltage Loop Powered 17 - 30 V
Quiescent Current 300uA @ 17 - 30 V Loop Powered  AM113-C AM113-D
  700uA @ 17 - 30 V Loop Powered AM113-S
Alarm Current 13mA AM113-C AM113-D
  1.1 mA AM113-S(No attachment devices)
Reset Time 20 seconds
Address Range 1-125
Temperature /Relative Humidity  -10°C to 55°C / 0 to 95% RH, no condensation or icing
 Dimensions / Weight  49 (L) x 25 (W) x 13 (H) mm / 18g
Addressable Module AM113 for Detectors, Call Points, Input, Output and  Beacon. 
Addressable Fire Alarm System for Micro Output Module/ Loop Sounder
Key Features :

With its small physical size and convenient 8 way DIL switch for address setting and configuration, the AM113 provides the facility to upgrade all the components of a conventional system to a full addressable system, making it an ideal solution for retrofitting installations. The AM113 is fully compatible with all standard addressable modules, addressable sounders, addressable manual call points facilitating extensions to
existing systems.
Device type selection is by means of switch 8 on the DIL. In Sounder mode the output is removed when a Silence Alarm signal is received from the control panel. In Output mode the output remains active until the system is reset.

Related Products:
Addressable Fire Alarm System for Micro Output Module/ Loop Sounder
Company Information
Addressable Fire Alarm System for Micro Output Module/ Loop Sounder

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now