  • Conventional Smoke and Heat Detector with Relay Output
  • Conventional Smoke and Heat Detector with Relay Output
  • Conventional Smoke and Heat Detector with Relay Output
  • Conventional Smoke and Heat Detector with Relay Output
  • Conventional Smoke and Heat Detector with Relay Output
  • Conventional Smoke and Heat Detector with Relay Output
Find Similar Products

Basic Info.

Model NO.
SD119-4H
Certification
CE, En
Application
Indoor
Working Principle
Electro-Optical Type
Transmission Mode
Cable
Alarm Volume (within 1m)
≥80dB
Receive Frequency
No
Color
White
Weight
130g/Set with Base(9V Battery Included)
Dimensions
102mm(Dia.)*35mm(Ht) with Base
Certificate
UL/En
Humidity
0 to 95% Rh, No Condensation or Icing
Smoke Sensitivity
0.08---0.14dB/M
Battery Availability
18months(Carbon Zinc); 3 Years(Alkaline); 10 Years
Name
Wireless Smoke Detector
Material
ABS
Alarm Sound Level
85 dB/3m
Transport Package
100PCS/Carton
Specification
EN14604
Trademark
Sentek
Origin
Ningbo China
HS Code
8531901000
Production Capacity
100000/Month

Product Description

Conventional Smoke and Heat Detector with Relay Output
Specification: 

Product Name:  Fire Smoke Alarm with UL Ce En 14604 ApprovalL

Model

SD119-4HARB

Smoke Sensitivity:

 UL268 or EN54-7 standard

Ceiling Spacing:

50 foot rating for heat sensor (55 degree)

Reset Voltage:

less than 1 volt

Reset Time:

less than 1 second

Alarm Indicator:

LED continuously emitting red light

Remote Output:

25 mA max., diode gate

Temperature Range:

-10°C to 55°C

Permissible Current:

80mA maximum

Humidity:

0 to 95% RH, no condensation or icing

Alarm Contact:

NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC

Dimensions:

100mm (dia) x 52mm (ht) with base

Weight:

130g/set with base

Conventional Smoke and Heat Detector with Relay Output
Conventional Smoke and Heat Detector with Relay Output
Conventional Smoke and Heat Detector with Relay Output
 Product Features: 
• 2 wire models
• Advanced detection and discrimination algorithms
• Easy installation and maintenance
• Sleek low-profi le housing design
• Durable sensor head, no need for replacement
• SMD circuit board design-satisfactory quality and reliability guaranteed
• Integrated heat detector for SD 119-2H 
• N/C (normal/close)-N/O (normal/open)selectable relay output
• AR (Auto Reset) function for security systems (optional for 4 wire models) 

The range includes:
SD-119-2                       2 wire photoelectric smoke alarm
SD-119-2L                     2 wire photoelectric smoke alarm with remote LED output
SD-119-2H                     2 wire photoelectric smoke and heat alarm
SD-119-2HL                   2 wire photoelectric smoke and heat alarm with remote LED output
SD-119-4-12/24             4 wire photoelectric smoke alarm (12/24VDC)
SD-119-4B-12/24           4 wire photoelectric smoke alarm with Buzzer (12V/24DC)
SD-119-4AR-12/24         4 wire photoelectric smoke alarm with auto-reset function (12/24VDC)
SD-119-4ARB-12/24       4 wire photoelectric smoke alarm with auto-reset function and Buzzer (12/24VDC)
SD-119-4H-12/24            4 wire photoelectric smoke and heat alarm (12V/24DC)
SD-119-4HB-12/24          4 wire photoelectric smoke and heat alarm with Buzzer (12/24VDC)
SD-119-4HAR-12/24        4 wire photoelectric smoke and heat alarm with auto-reset function (12/24VDC)
SD-119-4HARB-12/24      4 wire photoelectric smoke and heat alarm with auto-reset function with Buzzer (12/24VDC)

Model 2/4
wire
Heat
Sensor
Setting
Voltage
DC
(Min./Max.)
Standby
Current
(Max.)
Alarm
Current
(12/24V)
Surge
Current
(Max.)
Start-Up
Time
(Max.)
Permissible
Current
(Max.)
Cycle
Time
Alarm
contact
Certified Base
Model No.
SD119-2 2   10.8~33V 80μA 22/55mA 160μA 30 Sec. 80mA 1-3 Sec. - UL/EN P/N852001
SD119-2L 2   10.8~33V 80μA 22/55mA 160μA 30 Sec. 80mA 1-3 Sec. Remote LED UL/EN P/N852001
SD119-2H 2 135±5°F 10.8~33V 80μA 22/55mA 160μA 30 Sec. 80mA 1-3 Sec. - UL/EN P/N852001
SD119-2HL 2 135±5°F 10.8~33V 80μA 22/55mA 160μA 30 Sec. 80mA 1-3 Sec. Remote LED UL/EN P/N852001
SD119-4-12/24 4   12/24V 80μA 30/45mA - 30 Sec. - 1-3 Sec. Form A UL/EN P/N852001
SD119-4H-12/24 4 135±5°F 12/24V 80μA 30/45mA - 30 Sec. - 1-3 Sec. Form A UL/EN P/N852001
SD119-4AR-12/24 4   12/24V 100μA 30/45mA - 30 Sec. - 1-3 Sec. Form A
Auto Reset
CE P/N852001
SD119-4ARB-12/24 4   12/24V 100μA 30/45mA - 30 Sec. - 1-3 Sec. Form A
Auto Reset
CE P/N852001
SD119-4B-12/24 4   12/24V 80μA 30/45mA - 30 Sec. - 1-3 Sec. Form A CE P/N852001
SD119-4HB-12/24 4 135±5°F 12/24V 80μA 30/45mA - 30 Sec. - 1-3 Sec. Form A CE P/N852001
SD119-4HARB-12/24 4 135±5°F 12/24V 100μA 30/45mA - 30 Sec. - 1-3 Sec. Form A
Auto Reset
CE P/N852001

Related Product
Conventional Smoke and Heat Detector with Relay Output

Company Information

Conventional Smoke and Heat Detector with Relay Output

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier