Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)

Product Details
Customization: Available
Type: Home Alarm
Signal Transmission: Wired Alarm
Still deciding? Get samples of US$ 8/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
121
Year of Establishment
2005-11-14
  • Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
  • Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
  • Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
  • Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
  • Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
  • Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
Find Similar Products

Basic Info.

Model NO.
SD119-4ARB
Certification
CE, En
Application
Indoor
Color
White
Weight
120g/Set with Base
Dimensions
100mm(Dia.)*46mm(Ht) with Base
Certificate
UL/En
Alarm Indicator
LED Continuously Emitting Red Light
Ceiling Spacing
40-50 Foot Rating for Heat Sensor
Temperature Range
-10°c to 50°c
Name
Conventional Smoke Detector
Humidity
0 to 95% Rh, No Condensation or Icing
Smoke Sensitivity
0.98--2.40%/FT Obscuration (UL) ; 0.08--0.14 dB/M
Transport Package
100PCS/Carton
Specification
UL/EN
Trademark
Sentek
Origin
Ningbo China
HS Code
8531901000
Production Capacity
100000/Month

Product Description

Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
Specification:
 

Smoke Sensitivity: 0.98~4%/FT Obsuration(UL standard)
Ceiling Spacing: 50 foot rating for heat sensor (55 degree)
Reset Voltage: less than 1 volt
Reset Time: less than 1 second
Alarm Indicator: LED continuously emitting red light
Remote Output: 25 mA max., diode gate
Temperature Range: -10°C to 55°C,UL268 temperature 0~37.8 °C
Permissible Current: 80mA maximum
Humidity: 0 to 95% RH, no condensation or icing
Alarm Contact: (for 4-wire)NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VAC
Dimensions: 100mm (dia) x 46mm (ht) with base
Weight: 130g/set with base

Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)

Product Features: 

*2 or 4 wire 
*Advanced detection and discrimination algorithms 
*Easy installation and maintenance
*Sleek low-profile housing design
*Durable sensor head, no need for replacement 
*SMD circuit board design: satisfactory quality and reliability guaranteed
*N/C and N/O relay output  
*Auto reset function for security systems (4 wire optional ) Sensor base option:standard and Schottky Diode
*Five-year warranty

Order Information:

SD119-2:                  2 wire photoelectric smoke alarm

SD119-2-LED:          2 wire photoelectric smoke alarm with remote LED output

SD119-2H:                2 wire photoelectric smoke and heat alarm

SD119-2H-LED:        2 wire photoelectric smoke and heat alarm with remote LED output

SD119-4:                  4 wire photoelectric smoke alarm(12/24/48VDC)

SD119-4B:                4 wire photoelectric smoke alarm with Buzzer(12/24/48VDC)

SD119-4AR:              4 wire photoelectric smoke alarm with auto-reset function(12/24/48VDC)

SD119-4ARB:           4 wire photoelectric smoke alarm with auto-reset function and Buzzer(12/24/48VDC)

SD119-4H:                4 wire photoelectric smoke and heat alarm (12/24/48VDC)

SD119-4HB:             4 wire photoelectric smoke and heat alarm with Buzzer(12/24/48VDC)

SD119-4HAR:           4 wire photoelectric smoke and heat alarm with auto-reset function(12/24/48VDC)

Model

2/4

Wire

Heat Sensor Setting

Voltage DC

(Min./MAX.)

Standby Current

(Max.)

Alarm Current

(12/24V)

Surge Current

(Max.)

Start-Up Time

(Max.)

Permissible Current

(Max.)

Cycle Time Alarm Contact Certified
SD119-2 2   10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. - UL/EN
SD119-2L 2   10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. Remote LED UL/EN
SD119-2H 2 135±5°F 10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. - UL/EN
SD119-2HL 2 135±5°F 10.8-33V 80µA 22/55mA 160µA 30Sec. 80mA 1-3Sec. Remote LED UL/EN
SD119-4-12/24 4   12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A UL/EN
SD119-4H-12/24 4 135±5°F 12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A UL/EN
SD119-4AR-12/24 4   12/24V 100µA 30/45mA - 30Sec. - 1-3Sec.

Form A

Auto Reset

CE
SD119-4ARB-12/24 4   12/24V 100µA 30/45mA - 30Sec. - 1-3Sec.

Form A

Auto Reset

CE
SD119-4B-12/24 4   12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A CE
SD119-4HB-12/24 4 135±5°F 12/24V 80µA 30/45mA - 30Sec. - 1-3Sec. Form A CE
SD119-4HARB-12/24 4 135±5°F 12/24V 100µA 30/45mA - 30Sec. - 1-3Sec.

Form A

Auto Reset

CE

Related Products
Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)
Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)

Company Information

Conventional Smoke Fire Alarm with Remote LED Indicator (SD119-4ARB)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier